187 megawatts.
Built for the workloads the grid wasn’t.
AI training racks draw four to ten times the power of a traditional rack. Our power architecture was redesigned from the substation forward — utility feeds, UPS topology, on-site generation, and energy contracting — for that reality.
The architecture
From the substation to the rack.
Power for an AI-era data center is not a back-office concern — it is the binding constraint on what you can host, when you can host it, and how it scales. Our power architecture is designed end-to-end, from the substation step-down through the medium-voltage distribution, the UPS topology, the static transfer switches, and the rack-level power distribution units, against the requirements of 100 kW racks and the redundancy expectations of mission-critical tenants.
- N+1 utility feeds to every facility, with diverse-route redundancy.
- 2N UPS configuration available for tier-IV-class workloads.
- On-site backup generation sized for full facility load.
- Long-term PPA structures available for hyperscale customers.
Technical specifications
What you're committing to.
- Total committed capacity
- 187 MW across portfolio
- Utility configuration
- N+1 medium-voltage feeds
- UPS topology
- N+1 standard, 2N available
- On-site generation
- Backup generators sized for full IT load
- Static transfer switches
- Dual-source ATS at distribution level
- PDU topology
- 3-phase rack PDUs with intelligent metering
- PPA structures
- Wholesale, fixed-rate, indexed available
- Renewable integration
- Roadmap to 2029 — see Sustainability
Power architecture
The stack from substation to rack.
Utility entrance
Diverse medium-voltage feeds from independent substation paths. Step-down transformers in N+1 configuration.
UPS systems
E-series UPS systems in N+1 standard configuration. 2N option for tier-IV-class redundancy.
On-site generation
Diesel backup generators sized for full IT load with 72+ hours of fuel reserve. Tested under load monthly.
Static transfer switches
Dual-source ATS at distribution level. Sub-cycle transfer between sources — no perceptible interruption.
Finblade power monitoring
Real-time power telemetry from substation through PDU. Customer-facing dashboards for tenant transparency.
Renewable PPA roadmap
Long-term renewable PPAs scaling toward Vision 2030 targets. Solar and wind structures under negotiation.
Engagement models
How customers contract power.
Wholesale lease
Multi-megawatt leases at fixed rate or indexed structure. Power, space, and cooling delivered as a turnkey hall.
Learn moreCustomer-procured PPA
For hyperscalers with their own utility relationships, we facilitate direct PPAs with the customer as named offtaker.
Colocation power
For enterprise colocation, power is delivered on a per-kW basis with 2N or N+1 architecture per customer choice.
Learn more“Power is the constraint. Get the substation right, and everything downstream becomes engineering. Get it wrong, and no amount of clever cooling will save you.”
Capacity is being committed daily.
Reserve yours.
Tour the facility. Talk to engineering. Get a precision quote. We respond to qualified inquiries within one business day.