Platform · Power Architecture

187 megawatts.
Built for the workloads the grid wasn’t.

AI training racks draw four to ten times the power of a traditional rack. Our power architecture was redesigned from the substation forward — utility feeds, UPS topology, on-site generation, and energy contracting — for that reality.

Desert Dragon facility at the substation step-down

The architecture

From the substation to the rack.

Power for an AI-era data center is not a back-office concern — it is the binding constraint on what you can host, when you can host it, and how it scales. Our power architecture is designed end-to-end, from the substation step-down through the medium-voltage distribution, the UPS topology, the static transfer switches, and the rack-level power distribution units, against the requirements of 100 kW racks and the redundancy expectations of mission-critical tenants.

  • N+1 utility feeds to every facility, with diverse-route redundancy.
  • 2N UPS configuration available for tier-IV-class workloads.
  • On-site backup generation sized for full facility load.
  • Long-term PPA structures available for hyperscale customers.

Technical specifications

What you're committing to.

Power · Portfolio Capacity
Total committed capacity
187 MW across portfolio
Utility configuration
N+1 medium-voltage feeds
UPS topology
N+1 standard, 2N available
On-site generation
Backup generators sized for full IT load
Static transfer switches
Dual-source ATS at distribution level
PDU topology
3-phase rack PDUs with intelligent metering
PPA structures
Wholesale, fixed-rate, indexed available
Renewable integration
Roadmap to 2029 — see Sustainability

Power architecture

The stack from substation to rack.

Utility entrance

Diverse medium-voltage feeds from independent substation paths. Step-down transformers in N+1 configuration.

UPS systems

E-series UPS systems in N+1 standard configuration. 2N option for tier-IV-class redundancy.

On-site generation

Diesel backup generators sized for full IT load with 72+ hours of fuel reserve. Tested under load monthly.

Static transfer switches

Dual-source ATS at distribution level. Sub-cycle transfer between sources — no perceptible interruption.

Finblade power monitoring

Real-time power telemetry from substation through PDU. Customer-facing dashboards for tenant transparency.

Renewable PPA roadmap

Long-term renewable PPAs scaling toward Vision 2030 targets. Solar and wind structures under negotiation.

Engagement models

How customers contract power.

Wholesale lease

Multi-megawatt leases at fixed rate or indexed structure. Power, space, and cooling delivered as a turnkey hall.

Learn more

Customer-procured PPA

For hyperscalers with their own utility relationships, we facilitate direct PPAs with the customer as named offtaker.

Colocation power

For enterprise colocation, power is delivered on a per-kW basis with 2N or N+1 architecture per customer choice.

Learn more
“Power is the constraint. Get the substation right, and everything downstream becomes engineering. Get it wrong, and no amount of clever cooling will save you.”